The drain pan should be at least two inches deep and be at least two inches longer and wider than the water heater dimensions.
Texas water heater regulations.
504 7 water heater code requires a metal drain pan under the water heater if it is installed in an area where water can cause damage.
Subchapter n 65 206 and 65 214.
18 potable water heater means a boiler designed for operation at pressures not exceeding 160 pounds per square inch and water temperatures not exceeding 210 degrees fahrenheit if the boiler s.
This can be very difficult so most regulations allow you to use a drain pan instead.
A water heater installation requires a plumbing permit in texas since 2007 texas requires a plumbing permit for a water heater replacement.
You will also need to place the heater near a floor drain so that any water leaks will immediately drain out and away from the house.
Where a gas storage tank type water heater is installed in a location where water leakage from the tank will cause water damage the tank shall be installed in a galvanized steel pan having a material thickness of not less than 0 0236 inch.
In almost all circumstances replacing an existing water heater will require either one or two permits.
A few rare cases may also require a third permit.
The law affects gas powered and electric fueled tank style water heaters up to 55 gallons.
The clear access opening dimensions shall be not less than 20 inches by 30 inches 508 mm by 762 mm where such dimensions are large enough to allow removal of the water heater.
The permit requires a licensed plumber install the water heater in compliance with the state of texas any local municipality plumbing codes.
What specific hot water heater types do these regulations affect.
And subchapter r 65 603 and 65 607.
The rules and regulations for public water systems are established by the tceq in title 30 texas administrative code 30 tac chapter 290.
Since 2007 a plumbing permit has been needed to install a hot water heater in texas requiring a licensed plumber to tackle the project in accordance with state plumbing code.
A heat input exceeds 200 000 british thermal units per hour.
The texas commission of licensing and regulation commission adopts amendments to the boilers program rules at 16 texas administrative code chapter 65 subchapter a 65 2.
Water heaters must be installed to icc plumbing regulations in texas.
There are new regulations affecting units that hold more than 55 gallons but those units are conventional tank style water heaters.
This is as easy as heading down to the local planning or building department to ask for one.
A level service space not less than 30 inches 762 mm in length and 30 inches 762 mm in width shall be present at the front or service side of the water heater.